OhMyCalc

Base Plate Calculator

Size a steel column base plate based on column load and concrete strength.

How to Use the Base Plate Calculator

  1. Enter the column load in kilonewtons.
  2. Enter the concrete compressive strength in MPa.
  3. Click Calculate to get plate area, side, and thickness.

Casos de Uso

Fórmula

A = P / (0.85 × fc). Side = √A. Thickness ≈ 0.9 × side × √(fc/250).

Perguntas Frequentes

Why 0.85 × fc?
ACI 318 limits the bearing stress on concrete to 0.85 × fc when the bearing area equals the concrete area.
Is the thickness formula exact?
It is a simplified estimate. Full design uses the cantilever projection and plate yield strength.
What concrete strength is typical?
Commercial construction typically uses 25–40 MPa concrete.